Voltas AC Error Code List PDF

Voltas AC Error Code List PDF Download

Free download PDF of Voltas AC Error Code List using the direct link provided at the bottom of the PDF description.

DMCA / REPORT COPYRIGHT

Voltas AC Error Code List - Description

Dear readers, here we are offering Voltas AC Error Code List PDF to all of you. If your Air Conditioner is displaying a code other than the AC Error Code given below, then comment and tell. I will definitely answer you and also tell you the solution.  Voltas is a famous Indian Home appliance company. Tata Group is the parent organization of this Voltas. I have added only common and important errors in this table. Along with this, information on how to troubleshoot is also given. Voltas Limited is also known as one of the most successful Indian multinational consumer electronics companies. Its headquarter situated in Mumbai. If you are using the Voltas air conditioner, then you should have the Voltas AC error code list pdf so that you can manage it on your own. Remember that most air conditioner problems are caused by airflow or power requirements. If you are a Voltas AC customer and your AC is having problems and error codes are being displayed, then the table below will be helpful for you.

Voltas AC Error Code List PDF

Find the Voltas AC error codes below:

CODE

EXPLANATION

EE – The error code shows when you have an issue with Voltas indoor machine.
E0 – The error code shows when there is an issue with the outdoor machine EE.
E1 – The error code shows when you have an issue with the indoor fan.
E2 – The error code shows when you have an issue with zero-crossing detection indoor fan.
E3 – The error code shows when you have an issue with the sensor and indoor coil fault. You might need coil overheat protection.
E4 – The error code shows when there is an issue with your Voltas indoor ambient temperature sensor.
E5: The error code shows when there is a problem with the fan operation.
E6: The error code shows when there is an outdoor and indoor machine communication issue.
E8: The error code shows when there is a problem with outdoor communication.
F1: The error code shows when you have a problem with the compressor starting up.
F2: The error code shows when you have a problem with your compressor.
F3: The error code shows when you have a problem with the IPM module.
F4: The error code shows when you have a problem with the compressor shell roof.
F5: The error code shows when you have a problem with the discharge temperature sensor.
F6: The error code shows when you have a problem with the section temperature sensor.
F7: The error shows when you have a problem with the coil temperature sensor or there is a temperature sensor fault.
F8: The error code shows when you have a problem with the ambient temperature sensor.
F9: The error code shows when you have a problem with your outdoor DC fan.
P1: The error code shows when you have a problem with the machine air conditioning current protection.
P2: The error code shows when you have an issue with the compressor phase current protection.
P3: The error code shows when you have a problem with your outdoor unit air conditioner/ac voltage protection.
P4: The error code shows when you have a problem with the DC voltage protection.
P5: The error code shows when you have a problem with IPM over-high temperature protection.
P6: The error code shows when you have a problem with the discharge temperature overheat protection.
P7: The error code shows when you have a problem with the cooling coil anti-freezing protection.
L4: The error code shows when you have a problem with the phase current samping.
U1: The error code shows when there is a problem with the IPM overcurrent protection.
U3: The error code shows when you have a problem with the compressor overcurrent protection.
U4: The error code shows when you have a problem with over voltage protection.
U5: The error code shows when you have a problem with low-voltage protection.
U7: The error code shows when you have a problem with over-speed protection.
1E: Issue with outdoor unit room temperature sensor.
2E: Issue with unit pipe temperature sensor (outdoor unit).
3E: Issue with exhaust sensor.
4E: Module board needs to be replaced.
8E: Issue with PFC. Need to replace the module board.
H1: Automatic defrosting
H3: Halt for compressor overload protection.
H4: Overload protection
PL: protection against low voltage
C5: Jumper cap malfunction
  • E1, E2, F7, F1 – Indoor room sensor fault

The latest Voltas smart ACs come equipped with sensors in the indoor and outdoor unit that help judge the external temperature and calculate the workload. Therefore, it enables the AC to set the proper cooling temperature to provide optimal comfort to the user.

  • The E1, E2, F7, and F1 error codes indicate an indoor room sensor fault.

Please note that users cannot rectify this error. So, we recommend escalating the matter to the Voltas service engineers. Kindly note down your model number and the error code. It can help the service engineer locate the fault and repair the appliance by replacing the sensor.

  • E4, F6, H6, E5 – Indoor blower motor fault

The indoor blower motor, also known as the fan motor, is responsible for the fan speed that allows uniform distribution of cool air inside the room. The E4, F6, H6, and E5 error codes indicate a fault with the indoor blower. Usually, the capacitor becomes weak and requires replacement. The solution is to contact the Voltas service center and lodge a service complaint.

  • E6, E5 – Over current protection

Voltas ACs can function at varying input voltages. However, if the input voltage is outside the operational range of the AC, it flashes the E6 or E5 error code, depending on the model you use. This error code shows voltage or power fluctuations. You can wait for the voltage to stabilize and restart the AC. The error code would have vanished. If it persists, you can install a voltage stabilizer with an operational range beyond the AC’s scope. The error code should disappear. If it does not, you should contact the Voltas AC service technician. There can be a significant fault in the PCB circuit.

  • E0, 1-time blink – Indoor unit EEPROM parameter fault

The E0 1-time blink is a technical error code indicating a fault with the indoor unit EEPROM parameter. Maybe, the soldering would have loosened. But, it is better to contact the Voltas service technician and let them handle the job.

  • E1, 2-time blink – Indoor – Outdoor communication fault

The Voltas split AC has an indoor and outdoor unit connected through wires and pipes. If the connecting wiring is faulty or has snapped, the AC will display an E1 2-time blink error. The remedy is to check the wiring and rectify the communication error. If the wiring has snapped, we suggest replacing the wires instead of taping them together. The AC mechanic is the ideal person to handle this responsibility.

  • E2, 3-time blink – Zero current crossing fault

A fault in the general AC wiring that does not allow the current flow results in the Voltas AC indicating an E2 3-time blink error code. It is also known as zero current crossing fault, meaning no current flows to the AC unit. The remedy is to check the wiring and set it right. If you are not well versed with the wiring, you can book a service fault and let the qualified technician handle it.

  • E3, 4-time blink – Indoor fan speed out of control

The E3 4-time blink error is similar to the indoor blower motor error. Here, the fan speed goes out of control. It either spins too fast or much slower than usual. As a result, it affects the overall cooling performance of the Voltas AC. Again, there can be a fault with the fan motor or the capacitor. You must summon the Voltas AC mechanic and let him handle this fault.

  • E4, 5-time blink – Indoor temperature sensor fault

The indoor temperature sensor senses the indoor temperature to set the optimum cooling temperature. The E5 5-time blink error code suggests a fault with the indoor temperature sensor. The only remedy is to replace the sensor. So, we recommend booking a service fault online and requesting the Voltas service representative to look into the matter.

  • E5, 6-time blink – Indoor coil sensor fault

The E5 6-time blink error code signifies a fault with the indoor coil sensor. Users cannot rectify this fault on their own. Please allow the expert to handle the job. So, please book a service call and summon the Voltas service engineer qualified to rectify this fault. Usually, you need to replace the indoor coil sensor.

  • EC, 7-time blink – Refrigerant leak

The EC 7-time blink error code is crucial because it indicates a refrigerant leak situation. So, if there is a refrigerant leak or a reduction in the pressure, you must contact the Voltas AC service personnel to investigate the matter. The service engineer checks for leakages and replaces the pipes if necessary. They also fill the gas and check the pressure levels. The code vanishes after rectifying the underlying damage.

  • F0, 1-time blink – Overload Current Protection

Usually, Indian homes experience voltage and power fluctuations. Under such circumstances, the Voltas AC indicates the F0 1-time blink error code. You can check the current load to ensure that appliances are not overloaded with a specific power source. Check the wiring and voltage levels. We suggest having a separate current point for the AC and not using it with any other appliance. On rectifying the current or voltage situation, the error code vanishes.

  • F1, 2-time blink – Outdoor temperature sensor fault

The Voltas ACs come equipped with outdoor temperature sensors that sense the external temperature before setting the optimal cooling temperature indoors. This sensor is usually located behind the condenser on the outdoor unit. Any fault with this outdoor temperature sensor results in the F1 2-time blink error code. You must call the Voltas AC mechanic to set the matter right. It could require replacing the sensor.

  • F2, 3-time blink – Outdoor condenser sensor fault

The F-series error codes concern the outdoor unit. For example, the F2 3-time blink error code signifies a fault with the outdoor condenser sensor. The remedy is raising a service request and properly mentioning the error code and model number. The Voltas AC service engineer is the qualified person to replace the outdoor condenser sensor and resolve the matter.

  • F3, 4-time blink – Discharge pipe sensor fault

The Voltas AC outdoor unit has a discharge pipe with a sensor. Any fault with this sensor results in the F3 4-time blink error code. You can book a service fault with the Voltas authorized service center and summon a service engineer to rectify the matter. Usually, it requires replacing the discharge pipe sensor with a new one.

  • F4, 5-time blink – Outdoor EEPROM parameter fault

The F4 5-time blink error code signifies a fault with the Outdoor EEPROM parameter. Unfortunately, you cannot repair this fault on your own. So, the ideal solution is to book a service call and request the AC mechanic to investigate.

  • P1, 2-time blink – Over and low voltage fault

The P1 2-time blink error code indicates a problem with the input voltage. It can be either low or high. In any case, the AC might not function, especially if the input voltage fluctuates beyond the operating voltage range of the appliance. The solution is to check the voltage levels and use a voltage stabilizer. The error code should vanish after installing the voltage stabilizer.

Voltas Split AC Error Code List PDF

Sr.No.

Models 

IDU Code

1. 1.0T Voltas SAC 123V Dyb 4551992
2. 1.5T Voltas SAC 183V Dyb 4551993
3. SAC 123V DZU 4552240
4. SAC 183V DZU 4552241
5. 1.0T Voltas SAC 123V EY 4551977
6. 1.5T Voltas SAC 183V EY 4551978
7. 2.0T Voltas SAC 243V EY 4551979
8. 1.0T Voltas SAC 123V MY 4552005
9. Voltas SAC 123V MZO2 4552227
10. Voltas SAC 183V MZO2 4552230
11. SAC 123V MZM 4552226
12. SAC 125V MZM 4552228
13. Voltas SAC 12V MY 4551880
14. Voltas SAC 18V MY 4551881
15. 1.5T Voltas SAC 183V MY 4552006
16. SAC 183V MZM 4552229
17. SAC 185V MZM 4552231
18. Voltas SAC 123V Eya 4552096
19. Voltas SAC 183V Eya 4552097
20. Voltas SAC 243V Eya 4552098
21. SAC 103V EZL 4552209
22. SAC 123V EZL 4552210
23. SAC 183V EZL 4552215
24. SAC 243V EZL 4552220
25. Voltas SAC 18V EY-W Cool Only 4551811
26. Voltas SAC 18V EY-W All Weather 4551808
27. Voltas SAC 24V EY-W All Weather 4551809
28. Voltas SAC 12V EY-W Cool Only 4551810
29. Voltas SAC 15V EY-W Cool Only  4552020
30. Voltas SAC 12V EY-W All Weather 4551807
31. Voltas SAC 123V LY 4552095
32. SAC 123V LZK 4552211
33. 125V Crown AW 4552024
34. SAC 125VH CROWN 4552214
35. 185V Crown AW 4552025
36. SAC 185VH CROWN 4552218
37. Voltas SAC 173V IY 4552124
38. Voltas SAC 18V LY 4551719
39. Voltas SAC 18V IY 4551918
40. 1.5T Voltas SAC 183V IY 4551937
41. 1.5T Voltas SAC 183V IY-R 4552026
42. 1.0T Voltas SAC 125V DYe 4551958
43. 1.5T Voltas SAC 185V DYe 4551960
44. Voltas SAC 183V SY 4552140
45. Voltas SAC183V Sya 4552182
46. Voltas SAC 183V JY 4552191
47. Voltas SAC 183V Gys 4552183
48. Voltas SAC 183V SZS 4552233
49. Voltas SAC 183V SZS2 4552278
50. Voltas SAC 183V JZJ 4552234
51. Voltas SAC 183V MZJ3 4552252
52. Voltas SAC 183V MZJ2 4552253
53.  Voltas SAC 183V JZJ4 4552279
54. Voltas SAC 184V SZS 4552254
55. Voltas CU 183V Jyg 4552180
56. SAC 183V GZS2 (DGS&D) 4552299
57. Voltas SAC 183V JZCT 4552317
58. Voltas SAC 183V SZFT 4552314
59. Voltas SAC 184V JZCT 4552318
60. Voltas SAC 184V SZFT 4552315
61. Voltas SAC 124V SZS 4552269
62. Voltas SAC 124V SZS2 4552311
63. Voltas SAC 125V ZZS1 4552271
64. Voltas SAC 153V JZJ 4552245
65. Voltas SAC 173V JZJ 4552272
66. Voltas SAC 125V DZV 4552236
67. Voltas SAC 185V DZV 4552237
68. Voltas SAC 244V DZV 4552221
69. Voltas SAC 185V ZZV1 4552273
70. Voltas SAC 123V DZX(R-410A) 4552306
71. Voltas SAC 123V DZW-VIVE(R-410A) 4552362
72. Voltas SAC 153V DZX (R-410A) 4552494
73. Voltas SAC 173V JZJ(R32) 4552401
74. Voltas SAC 183V JZJ(R32) 4552407
75. Voltas SAC 183V CZJ(R32 4552405
76. Voltas SAC 183V IZI-Jewel (R-410A) 4552363
77. Voltas SAC 183V SZS(R32) 4552408
78. Voltas SAC 243V DZV(R-410A) 4552419
79. Voltas SAC 124V DZX(R-32) 4552393
80. Voltas SAC 124V DZX-Floral (R32) 4552394
81. Voltas SAC 184V SZS(R32) 4552409
82. Voltas SAC 184V SZS Floral(R32) 4552410
83. Voltas SAC 244V DZV(R-410A) 4552221
84. Voltas SAC 125V DZV(R-410A) 4552236
85. Voltas SAC 185V DZV2(R-410A) 4552348
86. Voltas SAC 125V DZX(R-32) 4552495
87. Voltas SAC 125V DZW(R-32) 4552396
88. Voltas SAC 155V DZW (R32) 4552399
89. Voltas SAC 185V JZJ (R32) 4552411
90. Voltas SAC 185V ADS (R32) 4552449
91. Voltas SAC 185V ADS-Floral (R32) 4552493
92. Voltas SAC 185V ZZY-IMR (R32) 4552416
93. Voltas SAC 245V DZV (R32) 4552420
94. Voltas SAC 245V ZZV(R32) 4552421
95. Voltas SAC 123V MZW-CHAMPAGNE(R-410A) 4552392
96. Voltas SAC 123V MZX-BLUE(R-410A) 4552391
97. Voltas SAC 173V WZJ Smart Voice AC(R32) 4552403
98. Voltas SAC 183V SZS5 4552345
99. Voltas SAC 155V JZJ5 4552353
100. Voltas SAC 183V SZS4 4552344
101. Voltas SAC 183V MZJ2(R32) 4552372
102. Voltas SAC 183V MZJ3(R32) 4552373
103. Voltas SAC 183V MZSC (R32) 4552445
104. Voltas SAC 183V MZSB (R32) 4552446
105. Voltas SAC 12V DY 4551741
106. Voltas SAC 18V DY 4551742
107. Voltas SAC 12V CY 4551798
108. Voltas SAC 18V CY 4551799
109. Voltas SAC 24V CY 4551800
110. Voltas SAC 12V DYa 4551877
111. Voltas SAC 18V DYa 4551878
112. Voltas SAC 24V DYa 4551879
113. Voltas SAC 18V DYe All Weather 4552022
114. Voltas SAC 24V DYe All Weather 4552023
115. VOLTAS SAC 183VCZT 4552239
116. VOLTAS SAC 123VCZT 4552238
117. VOLTAS SAC 183VDZU 4552241
118. VOLTAS SAC 123VDZU 4552240
119. Voltas SAC 125V DZV 4552236
120. Voltas SAC 185V DZV 4552237
121. Voltas SAC 123V CZT3(R32) 4552365
122. Voltas SAC 183V CZT3(R32 4552370
123. Voltas SAC 123V CZTT(R32) 4552366
124. Voltas SAC 183V CZTT(R32) 4552371
125. Voltas SAC 153V DZV (R32) 4552369

You can download Voltas AC Error Code List PDF by clicking on the following download button.

Download Voltas AC Error Code List PDF using below link

REPORT THISIf the download link of Voltas AC Error Code List PDF is not working or you feel any other problem with it, please Leave a Comment / Feedback. If Voltas AC Error Code List is a copyright material Report This by sending a mail at [email protected]. We will not be providing the file or link of a reported PDF or any source for downloading at any cost.

RELATED PDF FILES

Leave a Reply

Your email address will not be published. Required fields are marked *